Codici di Errore / Sense Codes


Le unità ottiche restituiscono codici di errore (o Sense codes come vengono chiamati nell'industria) quando succede qualche problema o anche solo per comunicare all'host (PC o applicazione) alcune situazioni.

Lo standard che descrive questi messaggi è MMC :

MMC-3 Revision 10e

Table A.1 
Logical Unit Sense Key, ASC and ASCQ Assignments 

SK  ASC  ASCQ
0 / 00 / 00      NO ADDITIONAL SENSE INFORMATION 
B / 00 / 06      I/O PROCESS TERMINATED
5 / 00 / 11      AUDIO PLAY OPERATION IN PROGRESS
5 / 00 / 12      AUDIO PLAY OPERATION PAUSED
5 / 00 / 13      AUDIO PLAY OPERATION SUCCESSFULLY COMPLETED
5 / 00 / 14      AUDIO PLAY OPERATION STOPPED DUE TO ERROR
5 / 00 / 15      NO CURRENT AUDIO STATUS TO RETURN
4 / 00 / 17      CLEANING REQUESTED
3 / 02 / 00      NO SEEK COMPLETE
2 / 04 / 00      LOGICAL UNIT NOT READY, CAUSE NOT REPORTABLE
2 / 04 / 01      LOGICAL UNIT IS IN PROCESS OF BECOMING READY
2 / 04 / 02      LOGICAL UNIT NOT READY, INITIALIZING CMD. REQUIRED
2 / 04 / 03      LOGICAL UNIT NOT READY, MANUAL INTERVENTION REQUIRED
2 / 04 / 04      LOGICAL UNIT NOT READY, FORMAT IN PROGRESS
2 / 04 / 07      LOGICAL UNIT NOT READY, OPERATION IN PROGRESS
2 / 04 / 08      LOGICAL UNIT NOT READY, LONG WRITE IN PROGRESS
4 / 05 / 00      LOGICAL UNIT DOES NOT RESPOND TO SELECTION
3 / 06 / 00      NO REFERENCE POSITION FOUND
5 / 07 / 00      MULTIPLE PERIPHERAL DEVICES SELECTED
4 / 08 / 00      LOGICAL UNIT COMMUNICATION FAILURE
4 / 08 / 01      LOGICAL UNIT COMMUNICATION TIME-OUT
4 / 08 / 02      LOGICAL UNIT COMMUNICATION PARITY ERROR
4 / 08 / 03      LOGICAL UNIT COMMUNICATION CRC ERROR (ULTRA-DMA/32)
4 / 09 / 00      TRACK FOLLOWING ERROR
4 / 09 / 01      TRACKING SERVO FAILURE
4 / 09 / 02      FOCUS SERVO FAILURE
4 / 09 / 03      SPINDLE SERVO FAILURE
4 / 09 / 04      HEAD SELECT FAULT
6 / 0A / 00      ERROR LOG OVERFLOW
1 / 0B / 00      WARNING
1 / 0B / 01      WARNING - SPECIFIED TEMPERATURE EXCEEDED
1 / 0B / 02      WARNING - ENCLOSURE DEGRADED
3 / 0C / 00      WRITE ERROR
3 / 0C / 07      WRITE ERROR - RECOVERY NEEDED
3 / 0C / 08      WRITE ERROR - RECOVERY FAILED
3 / 0C / 09      WRITE ERROR - LOSS OF STREAMING
3 / 0C / 0A      WRITE ERROR - PADDING BLOCKS ADDED
3 / 11 / 00      UNRECOVERED READ ERROR
3 / 11 / 01      READ RETRIES EXHAUSTED
3 / 11 / 02      ERROR TOO LONG TO CORRECT
3 / 11 / 05      L-EC UNCORRECTABLE ERROR
3 / 11 / 06      CIRC UNRECOVERED ERROR
3 / 11 / 0F      ERROR READING UPC/EAN NUMBER
3 / 11 / 10      ERROR READING ISRC NUMBER
B / 11 / 11      READ ERROR - LOSS OF STREAMING
3 / 15 / 00      RANDOM POSITIONING ERROR
3 / 15 / 01      MECHANICAL POSITIONING ERROR
3 / 15 / 02      POSITIONING ERROR DETECTED BY READ OF MEDIUM
1 / 17 / 00      RECOVERED DATA WITH NO ERROR CORRECTION APPLIED
1 / 17 / 01      RECOVERED DATA WITH RETRIES
1 / 17 / 02      RECOVERED DATA WITH POSITIVE HEAD OFFSET
1 / 17 / 03      RECOVERED DATA WITH NEGATIVE HEAD OFFSET
1 / 17 / 04      RECOVERED DATA WITH RETRIES AND/OR CIRC APPLIED
1 / 17 / 05      RECOVERED DATA USING PREVIOUS SECTOR ID
1 / 17 / 07      RECOVERED DATA WITHOUT ECC - RECOMMEND REASSIGNMENT
1 / 17 / 08      RECOVERED DATA WITHOUT ECC - RECOMMEND REWRITE
1 / 17 / 09      RECOVERED DATA WITHOUT ECC - DATA REWRITTEN
1 / 18 / 00      RECOVERED DATA WITH ERROR CORRECTION APPLIED
1 / 18 / 01      RECOVERED DATA WITH ERROR CORR. & RETRIES APPLIED
1 / 18 / 02      RECOVERED DATA - DATA AUTO-REALLOCATED
1 / 18 / 03      RECOVERED DATA WITH CIRC
1 / 18 / 04      RECOVERED DATA WITH L-EC
1 / 18 / 05      RECOVERED DATA . RECOMMEND REASSIGNMENT
1 / 18 / 06      RECOVERED DATA . RECOMMEND REWRITE
1 / 18 / 08      RECOVERED DATA  WITH LINKING
5 / 1A / 00      PARAMETER LIST LENGTH ERROR
4 / 1B / 00      SYNCHRONOUS DATA TRANSFER ERROR
A / 1D / 00      MISCOMPARE DURING VERIFY OPERATION
5 / 20 / 00      INVALID COMMAND OPERATION CODE
5 / 21 / 00      LOGICAL BLOCK ADDRESS OUT OF RANGE
5 / 21 / 01      INVALID ELEMENT ADDRESS
5 / 21 / 02      INVALID ADDRESS FOR WRITE
5 / 24 / 00      INVALID FIELD IN CDB
5 / 25 / 00      LOGICAL UNIT NOT SUPPORTED
5 / 26 / 00      INVALID FIELD IN PARAMETER LIST
5 / 26 / 01      PARAMETER NOT SUPPORTED
5 / 26 / 02      PARAMETER VALUE INVALID
5 / 26 / 03      THRESHOLD PARAMETERS NOT SUPPORTED
5 / 26 / 04      INVALID RELEASE OF ACTIVE PERSISTENT RESERVATION
5 / 27 / 00      WRITE PROTECTED
5 / 27 / 01      HARDWARE WRITE PROTECTED
5 / 27 / 02      LOGICAL UNIT SOFTWARE WRITE PROTECTED
5 / 27 / 03      ASSOCIATED WRITE PROTECT
5 / 27 / 04      PERSISTENT WRITE PROTECT
5 / 27 / 05      PERMANENT WRITE PROTECT
7 / 27 / 06      CONDITIONAL WRITE PROTECT
6 / 28 / 00      NOT READY TO READY CHANGE, MEDIUM MAY HAVE CHANGED
6 / 28 / 01      IMPORT OR EXPORT ELEMENT ACCESSED
6 / 29 / 00      POWER ON, RESET, OR BUS DEVICE RESET OCCURRED
6 / 29 / 01      POWER ON OCCURRED
6 / 29 / 02      SCSI BUS RESET OCCURRED
6 / 29 / 03      BUS DEVICE RESET FUNCTION OCCURRED
6 / 29 / 04      DEVICE INTERNAL RESET
6 / 2A / 00      PARAMETERS CHANGED
6 / 2A / 01      MODE PARAMETERS CHANGED
6 / 2A / 02      LOG PARAMETERS CHANGED
6 / 2A / 03      RESERVATIONS PREEMPTED
5 / 2B / 00      COPY CANNOT EXECUTE SINCE INITIATOR CANNOT DISCONNECT
5 / 2C / 00      COMMAND SEQUENCE ERROR
5 / 2C / 03      CURRENT PROGRAM AREA IS NOT EMPTY
5 / 2C / 04      CURRENT PROGRAM AREA IS EMPTY
6 / 2E / 00      INSUFFICIENT TIME FOR OPERATION
6 / 2F / 00      COMMANDS CLEARED BY ANOTHER INITIATOR
2 / 30 / 00      INCOMPATIBLE MEDIUM INSTALLED
2 / 30 / 01      CANNOT READ MEDIUM . UNKNOWN FORMAT
2 / 30 / 02      CANNOT READ MEDIUM . INCOMPATIBLE FORMAT
2 / 30 / 03      CLEANING CARTRIDGE INSTALLED
2 / 30 / 04      CANNOT WRITE MEDIUM . UNKNOWN FORMAT
2 / 30 / 05      CANNOT WRITE MEDIUM . INCOMPATIBLE FORMAT
2 / 30 / 06      CANNOT FORMAT MEDIUM . INCOMPATIBLE MEDIUM
2 / 30 / 07      CLEANING FAILURE
5 / 30 / 08      CANNOT WRITE . APPLICATION CODE MISMATCH
5 / 30 / 09      CURRENT SESSION NOT FIXATED FOR APPEND
5 / 30 / 10      MEDIUM NOT FORMATTED
3 / 31 / 00      MEDIUM FORMAT CORRUPTED
3 / 31 / 01      FORMAT COMMAND FAILED
3 / 31 / 02      ZONED FORMATTING FAILED DUE TO SPARE LINKING
  / 34 / 00      ENCLOSURE FAILURE
  / 35 / 00      ENCLOSURE SERVICES FAILURE
  / 35 / 01      UNSUPPORTED ENCLOSURE FUNCTION
  / 35 / 02      ENCLOSURE SERVICES UNAVAILABLE
  / 35 / 03      ENCLOSURE SERVICES TRANSFER FAILURE
  / 35 / 04      ENCLOSURE SERVICES TRANSFER REFUSED
1 / 37 / 00      ROUNDED PARAMETER
5 / 39 / 00      SAVING PARAMETERS NOT SUPPORTED
2 / 3A / 00      MEDIUM NOT PRESENT
2 / 3A / 01      MEDIUM NOT PRESENT - TRAY CLOSED
2 / 3A / 02      MEDIUM NOT PRESENT - TRAY OPEN
6 / 3B / 0D      MEDIUM DESTINATION ELEMENT FULL
6 / 3B / 0E      MEDIUM SOURCE ELEMENT EMPTY
6 / 3B / 0F      END OF MEDIUM REACHED
6 / 3B / 11      MEDIUM MAGAZINE NOT ACCESSIBLE
6 / 3B / 12      MEDIUM MAGAZINE REMOVED
6 / 3B / 13      MEDIUM MAGAZINE INSERTED
6 / 3B / 14      MEDIUM MAGAZINE LOCKED
6 / 3B / 15      MEDIUM MAGAZINE UNLOCKED
4 / 3B / 16      MECHANICAL POSITIONING OR CHANGER ERROR
5 / 3D / 00      INVALID BITS IN IDENTIFY MESSAGE
2 / 3E / 00      LOGICAL UNIT HAS NOT SELF-CONFIGURED YET
4 / 3E / 01      LOGICAL UNIT FAILURE
4 / 3E / 02      TIMEOUT ON LOGICAL UNIT
6 / 3F / 00      TARGET OPERATING CONDITIONS HAVE CHANGED
6 / 3F / 01      MICROCODE HAS BEEN CHANGED
6 / 3F / 02      CHANGED OPERATING DEFINITION
6 / 3F / 03      INQUIRY DATA HAS CHANGED
4 / 40 / NN      DIAGNOSTIC FAILURE ON COMPONENT NN (80H-FFH)
5 / 43 / 00      MESSAGE ERROR
4 / 44 / 00      INTERNAL TARGET FAILURE
B / 45 / 00      SELECT OR RESELECT FAILURE
4 / 46 / 00      UNSUCCESSFUL SOFT RESET
4 / 47 / 00      SCSI PARITY ERROR
B / 48 / 00      INITIATOR DETECTED ERROR MESSAGE RECEIVED
B / 49 / 00      INVALID MESSAGE ERROR
4 / 4A / 00      COMMAND PHASE ERROR
4 / 4B / 00      DATA PHASE ERROR
4 / 4C / 00      LOGICAL UNIT FAILED SELF-CONFIGURATION
B / 4D / NN      TAGGED OVERLAPPED COMMANDS (NN = QUEUE TAG)
B / 4E / 00      OVERLAPPED COMMANDS ATTEMPTED
3 / 51 / 00      ERASE FAILURE
3 / 51 / 01      ERASE FAILURE - INCOMPLETE ERASE OPERATION DETECTED
4 / 53 / 00      MEDIA LOAD OR EJECT FAILED
5 / 53 / 02      MEDIUM REMOVAL PREVENTED
5 / 55 / 00      SYSTEM RESOURCE FAILURE
3 / 57 / 00      UNABLE TO RECOVER TABLE-OF-CONTENTS
6 / 5A / 00      OPERATOR REQUEST OR STATE CHANGE INPUT
6 / 5A / 01      OPERATOR MEDIUM REMOVAL REQUEST
6 / 5A / 02      OPERATOR SELECTED WRITE PROTECT
6 / 5A / 03      OPERATOR SELECTED WRITE PERMIT
6 / 5B / 00      LOG EXCEPTION
6 / 5B / 01      THRESHOLD CONDITION MET
6 / 5B / 02      LOG COUNTER AT MAXIMUM
6 / 5B / 03      LOG LIST CODES EXHAUSTED
1 / 5D / 01      FAILURE PREDICTION THRESHOLD EXCEEDED . Predicted Media failure
1 / 5D / 02      LOGICAL UNIT FAILURE PREDICTION THRESHOLD EXCEEDED
1 / 5D / 03      FAILURE PREDICTION THRESHOLD EXCEEDED . Predicted Spare Area Exhaustin
1 / 5D / FF      FAILURE PREDICTION THRESHOLD EXCEEDED (FALSE)
6 / 5E / 00      LOW POWER CONDITION ON
6 / 5E / 01      IDLE CONDITION ACTIVATED BY TIMER
6 / 5E / 02      STANDBY CONDITION ACTIVATED BY TIMER
6 / 5E / 03      IDLE CONDITION ACTIVATED BY COMMAND
6 / 5E / 04      STANDBY CONDITION ACTIVATED BY COMMAND
5 / 63 / 00      END OF USER AREA ENCOUNTERED ON THIS TRACK
5 / 63 / 01      PACKET DOES NOT FIT IN AVAILABLE SPACE
5 / 64 / 00      ILLEGAL MODE FOR THIS TRACK
5 / 64 / 01      INVALID PACKET SIZE
4 / 65 / 00      VOLTAGE FAULT
5 / 6F / 00      COPY PROTECTION KEY EXCHANGE FAILURE . AUTHENTICATION FAILURE
5 / 6F / 01      COPY PROTECTION KEY EXCHANGE FAILURE . KEY NOT PRESENT
5 / 6F / 02      COPY PROTECTION KEY EXCHANGE FAILURE .KEY NOT ESTABLISHED
5 / 6F / 03      READ OF SCRAMBLED SECTOR WITHOUT AUTHENTICATION
5 / 6F / 04      MEDIA REGION CODE IS MISMATCHED TO LOGICAL UNIT REGION
5 / 6F / 05      LOGICAL UNIT REGION MUST BE PERMANENT/REGION RESET COUNT ERROR
3 / 72 / 00      SESSION FIXATION ERROR
3 / 72 / 01      SESSION FIXATION ERROR WRITING LEAD-IN
3 / 72 / 02      SESSION FIXATION ERROR WRITING LEAD-OUT
5 / 72 / 03      SESSION FIXATION ERROR . INCOMPLETE TRACK IN SESSION
5 / 72 / 04      EMPTY OR PARTIALLY WRITTEN RESERVED TRACK
5 / 72 / 05      NO MORE TRACK RESERVATIONS ALLOWED
3 / 73 / 00      CD CONTROL ERROR
1 / 73 / 01      POWER CALIBRATION AREA ALMOST FULL
3 / 73 / 02      POWER CALIBRATION AREA IS FULL
3 / 73 / 03      POWER CALIBRATION AREA ERROR
3 / 73 / 04      PROGRAM MEMORY AREA UPDATE FAILURE
3 / 73 / 05      PROGRAM MEMORY AREA IS FULL
3 / 73 / 06      RMA/PMA IS ALMOST FULL
0 / 00 / 00      NO ADDITIONAL SENSE INFORMATION
B / 00 / 06      I/O PROCESS TERMINATED
2 / 04 / 00      LOGICAL UNIT NOT READY, CAUSE NOT REPORTABLE
2 / 04 / 01      LOGICAL UNIT IS IN PROCESS OF BECOMING READY
2 / 04 / 02      LOGICAL UNIT NOT READY, INITIALIZING CMD. REQUIRED
2 / 04 / 03      LOGICAL UNIT NOT READY, MANUAL INTERVENTION REQUIRED
2 / 04 / 04      LOGICAL UNIT NOT READY, FORMAT IN PROGRESS
2 / 04 / 07      LOGICAL UNIT NOT READY, OPERATION IN PROGRESS
2 / 04 / 08      LOGICAL UNIT NOT READY, LONG WRITE IN PROGRESS
4 / 05 / 00      LOGICAL UNIT DOES NOT RESPOND TO SELECTION
5 / 07 / 00      MULTIPLE PERIPHERAL DEVICES SELECTED
4 / 08 / 00      LOGICAL UNIT COMMUNICATION FAILURE
4 / 08 / 01      LOGICAL UNIT COMMUNICATION TIME-OUT
4 / 08 / 02      LOGICAL UNIT COMMUNICATION PARITY ERROR
6 / 0A / 00      ERROR LOG OVERFLOW
1 / 0B / 00      WARNING
1 / 0B / 01      WARNING - SPECIFIED TEMPERATURE EXCEEDED
1 / 0B / 02      WARNING - ENCLOSURE DEGRADED
5 / 1A / 00      PARAMETER LIST LENGTH ERROR
4 / 1B / 00      SYNCHRONOUS DATA TRANSFER ERROR
5 / 20 / 00      INVALID COMMAND OPERATION CODE
5 / 24 / 00      INVALID FIELD IN CDB
5 / 25 / 00      LOGICAL UNIT NOT SUPPORTED
5 / 26 / 00      INVALID FIELD IN PARAMETER LIST
5 / 26 / 01      PARAMETER NOT SUPPORTED
5 / 26 / 02      PARAMETER VALUE INVALID
6 / 28 / 00      NOT READY TO READY CHANGE, MEDIUM MAY HAVE CHANGED
6 / 29 / 00      POWER ON, RESET, OR BUS DEVICE RESET OCCURRED
6 / 29 / 01      POWER ON OCCURRED
6 / 29 / 02      SCSI BUS RESET OCCURRED
6 / 29 / 03      BUS DEVICE RESET FUNCTION OCCURRED
6 / 29 / 04      DEVICE INTERNAL RESET
6 / 2A / 00      PARAMETERS CHANGED
6 / 2A / 01      MODE PARAMETERS CHANGED
6 / 2A / 02      LOG PARAMETERS CHANGED
6 / 2F / 00      COMMANDS CLEARED BY ANOTHER INITIATOR
  / 34 / 00      ENCLOSURE FAILURE
  / 35 / 00      ENCLOSURE SERVICES FAILURE
  / 35 / 01      UNSUPPORTED ENCLOSURE FUNCTION
  / 35 / 02      ENCLOSURE SERVICES UNAVAILABLE
  / 35 / 03      ENCLOSURE SERVICES TRANSFER FAILURE
  / 35 / 04      ENCLOSURE SERVICES TRANSFER REFUSED
5 / 3D / 00      INVALID BITS IN IDENTIFY MESSAGE
2 / 3E / 00      LOGICAL UNIT HAS NOT SELF-CONFIGURED YET
4 / 3E / 01      LOGICAL UNIT FAILURE
4 / 3E / 02      TIMEOUT ON LOGICAL UNIT
6 / 3F / 00      TARGET OPERATING CONDITIONS HAVE CHANGED
6 / 3F / 01      MICROCODE HAS BEEN CHANGED
6 / 3F / 02      CHANGED OPERATING DEFINITION
6 / 3F / 03      INQUIRY DATA HAS CHANGED
4 / 40 / NN      DIAGNOSTIC FAILURE ON COMPONENT NN (80H-FFH)
5 / 43 / 00      MESSAGE ERROR
4 / 44 / 00      INTERNAL TARGET FAILURE
B / 45 / 00      SELECT OR RESELECT FAILURE
4 / 46 / 00      UNSUCCESSFUL SOFT RESET
4 / 47 / 00      SCSI PARITY ERROR
B / 48 / 00      INITIATOR DETECTED ERROR MESSAGE RECEIVED
B / 49 / 00      INVALID MESSAGE ERROR
4 / 4A / 00      COMMAND PHASE ERROR
4 / 4B / 00      DATA PHASE ERROR
4 / 4C / 00      LOGICAL UNIT FAILED SELF-CONFIGURATION
B / 4D / NN      TAGGED OVERLAPPED COMMANDS (NN = QUEUE TAG)
B / 4E / 00      OVERLAPPED COMMANDS ATTEMPTED
6 / 5A / 00      OPERATOR REQUEST OR STATE CHANGE INPUT
6 / 5A / 01      OPERATOR MEDIUM REMOVAL REQUEST
6 / 5B / 00      LOG EXCEPTION
6 / 5B / 01      THRESHOLD CONDITION MET
6 / 5B / 02      LOG COUNTER AT MAXIMUM
6 / 5B / 03      LOG LIST CODES EXHAUSTED
6 / 5D / 00      FAILURE PREDICTION THRESHOLD EXCEEDED
6 / 5D / FF      FAILURE PREDICTION THRESHOLD EXCEEDED (FALSE)
4 / 65 / 00      VOLTAGE FAULT
4 / 00 / 17      CLEANING REQUESTED
3 / 02 / 00      NO SEEK COMPLETE
3 / 06 / 00      NO REFERENCE POSITION FOUND
4 / 09 / 00      TRACK FOLLOWING ERROR
4 / 09 / 01      TRACKING SERVO FAILURE
4 / 09 / 02      FOCUS SERVO FAILURE
4 / 09 / 03      SPINDLE SERVO FAILURE
4 / 09 / 04      HEAD SELECT FAULT
3 / 11 / 00      UNRECOVERED READ ERROR
3 / 11 / 01      READ RETRIES EXHAUSTED
3 / 11 / 02      ERROR TOO LONG TO CORRECT
3 / 11 / 05      L-EC UNCORRECTABLE ERROR
3 / 11 / 06      CIRC UNRECOVERED ERROR
3 / 11 / 0F      ERROR READING UPC/EAN NUMBER
3 / 11 / 10      ERROR READING ISRC NUMBER
3 / 15 / 00      RANDOM POSITIONING ERROR
3 / 15 / 01      MECHANICAL POSITIONING ERROR
3 / 15 / 02      POSITIONING ERROR DETECTED BY READ OF MEDIUM
1 / 17 / 00      RECOVERED DATA WITH NO ERROR CORRECTION APPLIED
1 / 17 / 01      RECOVERED DATA WITH RETRIES
1 / 17 / 02      RECOVERED DATA WITH POSITIVE HEAD OFFSET
1 / 17 / 03      RECOVERED DATA WITH NEGATIVE HEAD OFFSET
1 / 17 / 04      RECOVERED DATA WITH RETRIES AND/OR CIRC APPLIED
1 / 17 / 05      RECOVERED DATA USING PREVIOUS SECTOR ID
1 / 17 / 07      RECOVERED DATA WITHOUT ECC - RECOMMEND REASSIGNMENT
1 / 17 / 08      RECOVERED DATA WITHOUT ECC - RECOMMEND REWRITE
1 / 17 / 09      RECOVERED DATA WITHOUT ECC - DATA REWRITTEN
1 / 18 / 00      RECOVERED DATA WITH ERROR CORRECTION APPLIED
1 / 18 / 01      RECOVERED DATA WITH ERROR CORR. & RETRIES APPLIED
1 / 18 / 02      RECOVERED DATA - DATA AUTO-REALLOCATED
1 / 18 / 03      RECOVERED DATA WITH CIRC
1 / 18 / 04      RECOVERED DATA WITH L-EC
1 / 18 / 05      RECOVERED DATA . RECOMMEND REASSIGNMENT
1 / 18 / 06      RECOVERED DATA . RECOMMEND REWRITE
5 / 21 / 00      LOGICAL BLOCK ADDRESS OUT OF RANGE
2 / 30 / 00      INCOMPATIBLE MEDIUM INSTALLED
2 / 30 / 01      CANNOT READ MEDIUM . UNKNOWN FORMAT
2 / 30 / 02      CANNOT READ MEDIUM . INCOMPATIBLE FORMAT
2 / 30 / 03      CLEANING CARTRIDGE INSTALLED
2 / 30 / 07      CLEANING FAILURE
3 / 31 / 00      MEDIUM FORMAT CORRUPTED
2 / 3A / 00      MEDIUM NOT PRESENT
2 / 3A / 01      MEDIUM NOT PRESENT - TRAY CLOSED
2 / 3A / 02      MEDIUM NOT PRESENT - TRAY OPEN
3 / 57 / 00      UNABLE TO RECOVER TABLE-OF-CONTENTS
6 / 5E / 00      LOW POWER CONDITION ON
6 / 5E / 01      IDLE CONDITION ACTIVATED BY TIMER
6 / 5E / 02      STANDBY CONDITION ACTIVATED BY TIMER
6 / 5E / 03      IDLE CONDITION ACTIVATED BY COMMAND
6 / 5E / 04      STANDBY CONDITION ACTIVATED BY COMMAND
5 / 63 / 00      END OF USER AREA ENCOUNTERED ON THIS TRACK
5 / 64 / 00      ILLEGAL MODE FOR THIS TRACK
3 / 73 / 00      CD CONTROL ERROR
3 / 0C / 00      WRITE ERROR
3 / 0C / 07      WRITE ERROR - RECOVERY NEEDED
3 / 0C / 08      WRITE ERROR - RECOVERY FAILED
3 / 0C / 09      WRITE ERROR - LOSS OF STREAMING
3 / 0C / 0A      WRITE ERROR - PADDING BLOCKS ADDED
5 / 27 / 00      WRITE PROTECTED
5 / 27 / 01      HARDWARE WRITE PROTECTED
5 / 27 / 02      LOGICAL UNIT SOFTWARE WRITE PROTECTED
5 / 27 / 03      ASSOCIATED WRITE PROTECT
5 / 27 / 04      PERSISTENT WRITE PROTECT
5 / 27 / 05      PERMANENT WRITE PROTECT
2 / 30 / 04      CANNOT WRITE MEDIUM . UNKNOWN FORMAT
2 / 30 / 05      CANNOT WRITE MEDIUM . INCOMPATIBLE FORMAT
5 / 30 / 08      CANNOT WRITE . APPLICATION CODE MISMATCH
5 / 30 / 09      CURRENT SESSION NOT FIXATED FOR APPEND
5 / 30 / 10      MEDIUM NOT FORMATTED
6 / 5A / 02      OPERATOR SELECTED WRITE PROTECT
6 / 5A / 03      OPERATOR SELECTED WRITE PERMIT
1 / 73 / 01      POWER CALIBRATION AREA ALMOST FULL
3 / 73 / 02      POWER CALIBRATION AREA IS FULL
3 / 73 / 03      POWER CALIBRATION AREA ERROR
3 / 73 / 04      PROGRAM MEMORY AREA UPDATE FAILURE
3 / 73 / 05      PROGRAM MEMORY AREA IS FULL
5 / 2C / 03      CURRENT PROGRAM AREA IS NOT EMPTY
5 / 2C / 04      CURRENT PROGRAM AREA IS EMPTY
3 / 72 / 00      SESSION FIXATION ERROR
3 / 72 / 01      SESSION FIXATION ERROR WRITING LEAD-IN
3 / 72 / 02      SESSION FIXATION ERROR WRITING LEAD-OUT
5 / 72 / 03      SESSION FIXATION ERROR . INCOMPLETE TRACK IN SESSION
5 / 72 / 04      EMPTY OR PARTIALLY WRITTEN RESERVED TRACK

Note:
1.  Tutti i valori sono i esadecimale
2.  Quando non viene dato nessun valore per SK, l'errore è applicabile a diversi sense keys.