Fout codes


[Nog niet alle pagina's zijn vertaald.  Dit is een werk van lange adem.  Indien een bepaalde pagina u zeer interreseert maar nog moet vertaald worden, gelieve dan de exacte link naar deze pagina naar ons op te sturen met het verzoek prioriteit te geven aan de vertaling ervan.  Dank u.]

Optical drives return error codes (or Sense codes like they're called in the industry) when something is the matter or just to inform the host (PC, application) of a certain situation.

The standard that describes these messages (amongst other things) is MMC :

MMC-3 Revision 10e

Table A.1 
Logical Unit Sense Key, ASC and ASCQ Assignments 

SK  ASC  ASCQ
0 / 00 / 00      NO ADDITIONAL SENSE INFORMATION 
B / 00 / 06      I/O PROCESS TERMINATED
5 / 00 / 11      AUDIO PLAY OPERATION IN PROGRESS
5 / 00 / 12      AUDIO PLAY OPERATION PAUSED
5 / 00 / 13      AUDIO PLAY OPERATION SUCCESSFULLY COMPLETED
5 / 00 / 14      AUDIO PLAY OPERATION STOPPED DUE TO ERROR
5 / 00 / 15      NO CURRENT AUDIO STATUS TO RETURN
4 / 00 / 17      CLEANING REQUESTED
3 / 02 / 00      NO SEEK COMPLETE
2 / 04 / 00      LOGICAL UNIT NOT READY, CAUSE NOT REPORTABLE
2 / 04 / 01      LOGICAL UNIT IS IN PROCESS OF BECOMING READY
2 / 04 / 02      LOGICAL UNIT NOT READY, INITIALIZING CMD. REQUIRED
2 / 04 / 03      LOGICAL UNIT NOT READY, MANUAL INTERVENTION REQUIRED
2 / 04 / 04      LOGICAL UNIT NOT READY, FORMAT IN PROGRESS
2 / 04 / 07      LOGICAL UNIT NOT READY, OPERATION IN PROGRESS
2 / 04 / 08      LOGICAL UNIT NOT READY, LONG WRITE IN PROGRESS
4 / 05 / 00      LOGICAL UNIT DOES NOT RESPOND TO SELECTION
3 / 06 / 00      NO REFERENCE POSITION FOUND
5 / 07 / 00      MULTIPLE PERIPHERAL DEVICES SELECTED
4 / 08 / 00      LOGICAL UNIT COMMUNICATION FAILURE
4 / 08 / 01      LOGICAL UNIT COMMUNICATION TIME-OUT
4 / 08 / 02      LOGICAL UNIT COMMUNICATION PARITY ERROR
4 / 08 / 03      LOGICAL UNIT COMMUNICATION CRC ERROR (ULTRA-DMA/32)
4 / 09 / 00      TRACK FOLLOWING ERROR
4 / 09 / 01      TRACKING SERVO FAILURE
4 / 09 / 02      FOCUS SERVO FAILURE
4 / 09 / 03      SPINDLE SERVO FAILURE
4 / 09 / 04      HEAD SELECT FAULT
6 / 0A / 00      ERROR LOG OVERFLOW
1 / 0B / 00      WARNING
1 / 0B / 01      WARNING - SPECIFIED TEMPERATURE EXCEEDED
1 / 0B / 02      WARNING - ENCLOSURE DEGRADED
3 / 0C / 00      WRITE ERROR
3 / 0C / 07      WRITE ERROR - RECOVERY NEEDED
3 / 0C / 08      WRITE ERROR - RECOVERY FAILED
3 / 0C / 09      WRITE ERROR - LOSS OF STREAMING
3 / 0C / 0A      WRITE ERROR - PADDING BLOCKS ADDED
3 / 11 / 00      UNRECOVERED READ ERROR
3 / 11 / 01      READ RETRIES EXHAUSTED
3 / 11 / 02      ERROR TOO LONG TO CORRECT
3 / 11 / 05      L-EC UNCORRECTABLE ERROR
3 / 11 / 06      CIRC UNRECOVERED ERROR
3 / 11 / 0F      ERROR READING UPC/EAN NUMBER
3 / 11 / 10      ERROR READING ISRC NUMBER
B / 11 / 11      READ ERROR - LOSS OF STREAMING
3 / 15 / 00      RANDOM POSITIONING ERROR
3 / 15 / 01      MECHANICAL POSITIONING ERROR
3 / 15 / 02      POSITIONING ERROR DETECTED BY READ OF MEDIUM
1 / 17 / 00      RECOVERED DATA WITH NO ERROR CORRECTION APPLIED
1 / 17 / 01      RECOVERED DATA WITH RETRIES
1 / 17 / 02      RECOVERED DATA WITH POSITIVE HEAD OFFSET
1 / 17 / 03      RECOVERED DATA WITH NEGATIVE HEAD OFFSET
1 / 17 / 04      RECOVERED DATA WITH RETRIES AND/OR CIRC APPLIED
1 / 17 / 05      RECOVERED DATA USING PREVIOUS SECTOR ID
1 / 17 / 07      RECOVERED DATA WITHOUT ECC - RECOMMEND REASSIGNMENT
1 / 17 / 08      RECOVERED DATA WITHOUT ECC - RECOMMEND REWRITE
1 / 17 / 09      RECOVERED DATA WITHOUT ECC - DATA REWRITTEN
1 / 18 / 00      RECOVERED DATA WITH ERROR CORRECTION APPLIED
1 / 18 / 01      RECOVERED DATA WITH ERROR CORR. & RETRIES APPLIED
1 / 18 / 02      RECOVERED DATA - DATA AUTO-REALLOCATED
1 / 18 / 03      RECOVERED DATA WITH CIRC
1 / 18 / 04      RECOVERED DATA WITH L-EC
1 / 18 / 05      RECOVERED DATA . RECOMMEND REASSIGNMENT
1 / 18 / 06      RECOVERED DATA . RECOMMEND REWRITE
1 / 18 / 08      RECOVERED DATA  WITH LINKING
5 / 1A / 00      PARAMETER LIST LENGTH ERROR
4 / 1B / 00      SYNCHRONOUS DATA TRANSFER ERROR
A / 1D / 00      MISCOMPARE DURING VERIFY OPERATION
5 / 20 / 00      INVALID COMMAND OPERATION CODE
5 / 21 / 00      LOGICAL BLOCK ADDRESS OUT OF RANGE
5 / 21 / 01      INVALID ELEMENT ADDRESS
5 / 21 / 02      INVALID ADDRESS FOR WRITE
5 / 24 / 00      INVALID FIELD IN CDB
5 / 25 / 00      LOGICAL UNIT NOT SUPPORTED
5 / 26 / 00      INVALID FIELD IN PARAMETER LIST
5 / 26 / 01      PARAMETER NOT SUPPORTED
5 / 26 / 02      PARAMETER VALUE INVALID
5 / 26 / 03      THRESHOLD PARAMETERS NOT SUPPORTED
5 / 26 / 04      INVALID RELEASE OF ACTIVE PERSISTENT RESERVATION
5 / 27 / 00      WRITE PROTECTED
5 / 27 / 01      HARDWARE WRITE PROTECTED
5 / 27 / 02      LOGICAL UNIT SOFTWARE WRITE PROTECTED
5 / 27 / 03      ASSOCIATED WRITE PROTECT
5 / 27 / 04      PERSISTENT WRITE PROTECT
5 / 27 / 05      PERMANENT WRITE PROTECT
7 / 27 / 06      CONDITIONAL WRITE PROTECT
6 / 28 / 00      NOT READY TO READY CHANGE, MEDIUM MAY HAVE CHANGED
6 / 28 / 01      IMPORT OR EXPORT ELEMENT ACCESSED
6 / 29 / 00      POWER ON, RESET, OR BUS DEVICE RESET OCCURRED
6 / 29 / 01      POWER ON OCCURRED
6 / 29 / 02      SCSI BUS RESET OCCURRED
6 / 29 / 03      BUS DEVICE RESET FUNCTION OCCURRED
6 / 29 / 04      DEVICE INTERNAL RESET
6 / 2A / 00      PARAMETERS CHANGED
6 / 2A / 01      MODE PARAMETERS CHANGED
6 / 2A / 02      LOG PARAMETERS CHANGED
6 / 2A / 03      RESERVATIONS PREEMPTED
5 / 2B / 00      COPY CANNOT EXECUTE SINCE INITIATOR CANNOT DISCONNECT
5 / 2C / 00      COMMAND SEQUENCE ERROR
5 / 2C / 03      CURRENT PROGRAM AREA IS NOT EMPTY
5 / 2C / 04      CURRENT PROGRAM AREA IS EMPTY
6 / 2E / 00      INSUFFICIENT TIME FOR OPERATION
6 / 2F / 00      COMMANDS CLEARED BY ANOTHER INITIATOR
2 / 30 / 00      INCOMPATIBLE MEDIUM INSTALLED
2 / 30 / 01      CANNOT READ MEDIUM . UNKNOWN FORMAT
2 / 30 / 02      CANNOT READ MEDIUM . INCOMPATIBLE FORMAT
2 / 30 / 03      CLEANING CARTRIDGE INSTALLED
2 / 30 / 04      CANNOT WRITE MEDIUM . UNKNOWN FORMAT
2 / 30 / 05      CANNOT WRITE MEDIUM . INCOMPATIBLE FORMAT
2 / 30 / 06      CANNOT FORMAT MEDIUM . INCOMPATIBLE MEDIUM
2 / 30 / 07      CLEANING FAILURE
5 / 30 / 08      CANNOT WRITE . APPLICATION CODE MISMATCH
5 / 30 / 09      CURRENT SESSION NOT FIXATED FOR APPEND
5 / 30 / 10      MEDIUM NOT FORMATTED
3 / 31 / 00      MEDIUM FORMAT CORRUPTED
3 / 31 / 01      FORMAT COMMAND FAILED
3 / 31 / 02      ZONED FORMATTING FAILED DUE TO SPARE LINKING
  / 34 / 00      ENCLOSURE FAILURE
  / 35 / 00      ENCLOSURE SERVICES FAILURE
  / 35 / 01      UNSUPPORTED ENCLOSURE FUNCTION
  / 35 / 02      ENCLOSURE SERVICES UNAVAILABLE
  / 35 / 03      ENCLOSURE SERVICES TRANSFER FAILURE
  / 35 / 04      ENCLOSURE SERVICES TRANSFER REFUSED
1 / 37 / 00      ROUNDED PARAMETER
5 / 39 / 00      SAVING PARAMETERS NOT SUPPORTED
2 / 3A / 00      MEDIUM NOT PRESENT
2 / 3A / 01      MEDIUM NOT PRESENT - TRAY CLOSED
2 / 3A / 02      MEDIUM NOT PRESENT - TRAY OPEN
6 / 3B / 0D      MEDIUM DESTINATION ELEMENT FULL
6 / 3B / 0E      MEDIUM SOURCE ELEMENT EMPTY
6 / 3B / 0F      END OF MEDIUM REACHED
6 / 3B / 11      MEDIUM MAGAZINE NOT ACCESSIBLE
6 / 3B / 12      MEDIUM MAGAZINE REMOVED
6 / 3B / 13      MEDIUM MAGAZINE INSERTED
6 / 3B / 14      MEDIUM MAGAZINE LOCKED
6 / 3B / 15      MEDIUM MAGAZINE UNLOCKED
4 / 3B / 16      MECHANICAL POSITIONING OR CHANGER ERROR
5 / 3D / 00      INVALID BITS IN IDENTIFY MESSAGE
2 / 3E / 00      LOGICAL UNIT HAS NOT SELF-CONFIGURED YET
4 / 3E / 01      LOGICAL UNIT FAILURE
4 / 3E / 02      TIMEOUT ON LOGICAL UNIT
6 / 3F / 00      TARGET OPERATING CONDITIONS HAVE CHANGED
6 / 3F / 01      MICROCODE HAS BEEN CHANGED
6 / 3F / 02      CHANGED OPERATING DEFINITION
6 / 3F / 03      INQUIRY DATA HAS CHANGED
4 / 40 / NN      DIAGNOSTIC FAILURE ON COMPONENT NN (80H-FFH)
5 / 43 / 00      MESSAGE ERROR
4 / 44 / 00      INTERNAL TARGET FAILURE
B / 45 / 00      SELECT OR RESELECT FAILURE
4 / 46 / 00      UNSUCCESSFUL SOFT RESET
4 / 47 / 00      SCSI PARITY ERROR
B / 48 / 00      INITIATOR DETECTED ERROR MESSAGE RECEIVED
B / 49 / 00      INVALID MESSAGE ERROR
4 / 4A / 00      COMMAND PHASE ERROR
4 / 4B / 00      DATA PHASE ERROR
4 / 4C / 00      LOGICAL UNIT FAILED SELF-CONFIGURATION
B / 4D / NN      TAGGED OVERLAPPED COMMANDS (NN = QUEUE TAG)
B / 4E / 00      OVERLAPPED COMMANDS ATTEMPTED
3 / 51 / 00      ERASE FAILURE
3 / 51 / 01      ERASE FAILURE - INCOMPLETE ERASE OPERATION DETECTED
4 / 53 / 00      MEDIA LOAD OR EJECT FAILED
5 / 53 / 02      MEDIUM REMOVAL PREVENTED
5 / 55 / 00      SYSTEM RESOURCE FAILURE
3 / 57 / 00      UNABLE TO RECOVER TABLE-OF-CONTENTS
6 / 5A / 00      OPERATOR REQUEST OR STATE CHANGE INPUT
6 / 5A / 01      OPERATOR MEDIUM REMOVAL REQUEST
6 / 5A / 02      OPERATOR SELECTED WRITE PROTECT
6 / 5A / 03      OPERATOR SELECTED WRITE PERMIT
6 / 5B / 00      LOG EXCEPTION
6 / 5B / 01      THRESHOLD CONDITION MET
6 / 5B / 02      LOG COUNTER AT MAXIMUM
6 / 5B / 03      LOG LIST CODES EXHAUSTED
1 / 5D / 01      FAILURE PREDICTION THRESHOLD EXCEEDED . Predicted Media failure
1 / 5D / 02      LOGICAL UNIT FAILURE PREDICTION THRESHOLD EXCEEDED
1 / 5D / 03      FAILURE PREDICTION THRESHOLD EXCEEDED . Predicted Spare Area Exhaustin
1 / 5D / FF      FAILURE PREDICTION THRESHOLD EXCEEDED (FALSE)
6 / 5E / 00      LOW POWER CONDITION ON
6 / 5E / 01      IDLE CONDITION ACTIVATED BY TIMER
6 / 5E / 02      STANDBY CONDITION ACTIVATED BY TIMER
6 / 5E / 03      IDLE CONDITION ACTIVATED BY COMMAND
6 / 5E / 04      STANDBY CONDITION ACTIVATED BY COMMAND
5 / 63 / 00      END OF USER AREA ENCOUNTERED ON THIS TRACK
5 / 63 / 01      PACKET DOES NOT FIT IN AVAILABLE SPACE
5 / 64 / 00      ILLEGAL MODE FOR THIS TRACK
5 / 64 / 01      INVALID PACKET SIZE
4 / 65 / 00      VOLTAGE FAULT
5 / 6F / 00      COPY PROTECTION KEY EXCHANGE FAILURE . AUTHENTICATION FAILURE
5 / 6F / 01      COPY PROTECTION KEY EXCHANGE FAILURE . KEY NOT PRESENT
5 / 6F / 02      COPY PROTECTION KEY EXCHANGE FAILURE .KEY NOT ESTABLISHED
5 / 6F / 03      READ OF SCRAMBLED SECTOR WITHOUT AUTHENTICATION
5 / 6F / 04      MEDIA REGION CODE IS MISMATCHED TO LOGICAL UNIT REGION
5 / 6F / 05      LOGICAL UNIT REGION MUST BE PERMANENT/REGION RESET COUNT ERROR
3 / 72 / 00      SESSION FIXATION ERROR
3 / 72 / 01      SESSION FIXATION ERROR WRITING LEAD-IN
3 / 72 / 02      SESSION FIXATION ERROR WRITING LEAD-OUT
5 / 72 / 03      SESSION FIXATION ERROR . INCOMPLETE TRACK IN SESSION
5 / 72 / 04      EMPTY OR PARTIALLY WRITTEN RESERVED TRACK
5 / 72 / 05      NO MORE TRACK RESERVATIONS ALLOWED
3 / 73 / 00      CD CONTROL ERROR
1 / 73 / 01      POWER CALIBRATION AREA ALMOST FULL
3 / 73 / 02      POWER CALIBRATION AREA IS FULL
3 / 73 / 03      POWER CALIBRATION AREA ERROR
3 / 73 / 04      PROGRAM MEMORY AREA UPDATE FAILURE
3 / 73 / 05      PROGRAM MEMORY AREA IS FULL
3 / 73 / 06      RMA/PMA IS ALMOST FULL
0 / 00 / 00      NO ADDITIONAL SENSE INFORMATION
B / 00 / 06      I/O PROCESS TERMINATED
2 / 04 / 00      LOGICAL UNIT NOT READY, CAUSE NOT REPORTABLE
2 / 04 / 01      LOGICAL UNIT IS IN PROCESS OF BECOMING READY
2 / 04 / 02      LOGICAL UNIT NOT READY, INITIALIZING CMD. REQUIRED
2 / 04 / 03      LOGICAL UNIT NOT READY, MANUAL INTERVENTION REQUIRED
2 / 04 / 04      LOGICAL UNIT NOT READY, FORMAT IN PROGRESS
2 / 04 / 07      LOGICAL UNIT NOT READY, OPERATION IN PROGRESS
2 / 04 / 08      LOGICAL UNIT NOT READY, LONG WRITE IN PROGRESS
4 / 05 / 00      LOGICAL UNIT DOES NOT RESPOND TO SELECTION
5 / 07 / 00      MULTIPLE PERIPHERAL DEVICES SELECTED
4 / 08 / 00      LOGICAL UNIT COMMUNICATION FAILURE
4 / 08 / 01      LOGICAL UNIT COMMUNICATION TIME-OUT
4 / 08 / 02      LOGICAL UNIT COMMUNICATION PARITY ERROR
6 / 0A / 00      ERROR LOG OVERFLOW
1 / 0B / 00      WARNING
1 / 0B / 01      WARNING - SPECIFIED TEMPERATURE EXCEEDED
1 / 0B / 02      WARNING - ENCLOSURE DEGRADED
5 / 1A / 00      PARAMETER LIST LENGTH ERROR
4 / 1B / 00      SYNCHRONOUS DATA TRANSFER ERROR
5 / 20 / 00      INVALID COMMAND OPERATION CODE
5 / 24 / 00      INVALID FIELD IN CDB
5 / 25 / 00      LOGICAL UNIT NOT SUPPORTED
5 / 26 / 00      INVALID FIELD IN PARAMETER LIST
5 / 26 / 01      PARAMETER NOT SUPPORTED
5 / 26 / 02      PARAMETER VALUE INVALID
6 / 28 / 00      NOT READY TO READY CHANGE, MEDIUM MAY HAVE CHANGED
6 / 29 / 00      POWER ON, RESET, OR BUS DEVICE RESET OCCURRED
6 / 29 / 01      POWER ON OCCURRED
6 / 29 / 02      SCSI BUS RESET OCCURRED
6 / 29 / 03      BUS DEVICE RESET FUNCTION OCCURRED
6 / 29 / 04      DEVICE INTERNAL RESET
6 / 2A / 00      PARAMETERS CHANGED
6 / 2A / 01      MODE PARAMETERS CHANGED
6 / 2A / 02      LOG PARAMETERS CHANGED
6 / 2F / 00      COMMANDS CLEARED BY ANOTHER INITIATOR
  / 34 / 00      ENCLOSURE FAILURE
  / 35 / 00      ENCLOSURE SERVICES FAILURE
  / 35 / 01      UNSUPPORTED ENCLOSURE FUNCTION
  / 35 / 02      ENCLOSURE SERVICES UNAVAILABLE
  / 35 / 03      ENCLOSURE SERVICES TRANSFER FAILURE
  / 35 / 04      ENCLOSURE SERVICES TRANSFER REFUSED
5 / 3D / 00      INVALID BITS IN IDENTIFY MESSAGE
2 / 3E / 00      LOGICAL UNIT HAS NOT SELF-CONFIGURED YET
4 / 3E / 01      LOGICAL UNIT FAILURE
4 / 3E / 02      TIMEOUT ON LOGICAL UNIT
6 / 3F / 00      TARGET OPERATING CONDITIONS HAVE CHANGED
6 / 3F / 01      MICROCODE HAS BEEN CHANGED
6 / 3F / 02      CHANGED OPERATING DEFINITION
6 / 3F / 03      INQUIRY DATA HAS CHANGED
4 / 40 / NN      DIAGNOSTIC FAILURE ON COMPONENT NN (80H-FFH)
5 / 43 / 00      MESSAGE ERROR
4 / 44 / 00      INTERNAL TARGET FAILURE
B / 45 / 00      SELECT OR RESELECT FAILURE
4 / 46 / 00      UNSUCCESSFUL SOFT RESET
4 / 47 / 00      SCSI PARITY ERROR
B / 48 / 00      INITIATOR DETECTED ERROR MESSAGE RECEIVED
B / 49 / 00      INVALID MESSAGE ERROR
4 / 4A / 00      COMMAND PHASE ERROR
4 / 4B / 00      DATA PHASE ERROR
4 / 4C / 00      LOGICAL UNIT FAILED SELF-CONFIGURATION
B / 4D / NN      TAGGED OVERLAPPED COMMANDS (NN = QUEUE TAG)
B / 4E / 00      OVERLAPPED COMMANDS ATTEMPTED
6 / 5A / 00      OPERATOR REQUEST OR STATE CHANGE INPUT
6 / 5A / 01      OPERATOR MEDIUM REMOVAL REQUEST
6 / 5B / 00      LOG EXCEPTION
6 / 5B / 01      THRESHOLD CONDITION MET
6 / 5B / 02      LOG COUNTER AT MAXIMUM
6 / 5B / 03      LOG LIST CODES EXHAUSTED
6 / 5D / 00      FAILURE PREDICTION THRESHOLD EXCEEDED
6 / 5D / FF      FAILURE PREDICTION THRESHOLD EXCEEDED (FALSE)
4 / 65 / 00      VOLTAGE FAULT
4 / 00 / 17      CLEANING REQUESTED
3 / 02 / 00      NO SEEK COMPLETE
3 / 06 / 00      NO REFERENCE POSITION FOUND
4 / 09 / 00      TRACK FOLLOWING ERROR
4 / 09 / 01      TRACKING SERVO FAILURE
4 / 09 / 02      FOCUS SERVO FAILURE
4 / 09 / 03      SPINDLE SERVO FAILURE
4 / 09 / 04      HEAD SELECT FAULT
3 / 11 / 00      UNRECOVERED READ ERROR
3 / 11 / 01      READ RETRIES EXHAUSTED
3 / 11 / 02      ERROR TOO LONG TO CORRECT
3 / 11 / 05      L-EC UNCORRECTABLE ERROR
3 / 11 / 06      CIRC UNRECOVERED ERROR
3 / 11 / 0F      ERROR READING UPC/EAN NUMBER
3 / 11 / 10      ERROR READING ISRC NUMBER
3 / 15 / 00      RANDOM POSITIONING ERROR
3 / 15 / 01      MECHANICAL POSITIONING ERROR
3 / 15 / 02      POSITIONING ERROR DETECTED BY READ OF MEDIUM
1 / 17 / 00      RECOVERED DATA WITH NO ERROR CORRECTION APPLIED
1 / 17 / 01      RECOVERED DATA WITH RETRIES
1 / 17 / 02      RECOVERED DATA WITH POSITIVE HEAD OFFSET
1 / 17 / 03      RECOVERED DATA WITH NEGATIVE HEAD OFFSET
1 / 17 / 04      RECOVERED DATA WITH RETRIES AND/OR CIRC APPLIED
1 / 17 / 05      RECOVERED DATA USING PREVIOUS SECTOR ID
1 / 17 / 07      RECOVERED DATA WITHOUT ECC - RECOMMEND REASSIGNMENT
1 / 17 / 08      RECOVERED DATA WITHOUT ECC - RECOMMEND REWRITE
1 / 17 / 09      RECOVERED DATA WITHOUT ECC - DATA REWRITTEN
1 / 18 / 00      RECOVERED DATA WITH ERROR CORRECTION APPLIED
1 / 18 / 01      RECOVERED DATA WITH ERROR CORR. & RETRIES APPLIED
1 / 18 / 02      RECOVERED DATA - DATA AUTO-REALLOCATED
1 / 18 / 03      RECOVERED DATA WITH CIRC
1 / 18 / 04      RECOVERED DATA WITH L-EC
1 / 18 / 05      RECOVERED DATA . RECOMMEND REASSIGNMENT
1 / 18 / 06      RECOVERED DATA . RECOMMEND REWRITE
5 / 21 / 00      LOGICAL BLOCK ADDRESS OUT OF RANGE
2 / 30 / 00      INCOMPATIBLE MEDIUM INSTALLED
2 / 30 / 01      CANNOT READ MEDIUM . UNKNOWN FORMAT
2 / 30 / 02      CANNOT READ MEDIUM . INCOMPATIBLE FORMAT
2 / 30 / 03      CLEANING CARTRIDGE INSTALLED
2 / 30 / 07      CLEANING FAILURE
3 / 31 / 00      MEDIUM FORMAT CORRUPTED
2 / 3A / 00      MEDIUM NOT PRESENT
2 / 3A / 01      MEDIUM NOT PRESENT - TRAY CLOSED
2 / 3A / 02      MEDIUM NOT PRESENT - TRAY OPEN
3 / 57 / 00      UNABLE TO RECOVER TABLE-OF-CONTENTS
6 / 5E / 00      LOW POWER CONDITION ON
6 / 5E / 01      IDLE CONDITION ACTIVATED BY TIMER
6 / 5E / 02      STANDBY CONDITION ACTIVATED BY TIMER
6 / 5E / 03      IDLE CONDITION ACTIVATED BY COMMAND
6 / 5E / 04      STANDBY CONDITION ACTIVATED BY COMMAND
5 / 63 / 00      END OF USER AREA ENCOUNTERED ON THIS TRACK
5 / 64 / 00      ILLEGAL MODE FOR THIS TRACK
3 / 73 / 00      CD CONTROL ERROR
3 / 0C / 00      WRITE ERROR
3 / 0C / 07      WRITE ERROR - RECOVERY NEEDED
3 / 0C / 08      WRITE ERROR - RECOVERY FAILED
3 / 0C / 09      WRITE ERROR - LOSS OF STREAMING
3 / 0C / 0A      WRITE ERROR - PADDING BLOCKS ADDED
5 / 27 / 00      WRITE PROTECTED
5 / 27 / 01      HARDWARE WRITE PROTECTED
5 / 27 / 02      LOGICAL UNIT SOFTWARE WRITE PROTECTED
5 / 27 / 03      ASSOCIATED WRITE PROTECT
5 / 27 / 04      PERSISTENT WRITE PROTECT
5 / 27 / 05      PERMANENT WRITE PROTECT
2 / 30 / 04      CANNOT WRITE MEDIUM . UNKNOWN FORMAT
2 / 30 / 05      CANNOT WRITE MEDIUM . INCOMPATIBLE FORMAT
5 / 30 / 08      CANNOT WRITE . APPLICATION CODE MISMATCH
5 / 30 / 09      CURRENT SESSION NOT FIXATED FOR APPEND
5 / 30 / 10      MEDIUM NOT FORMATTED
6 / 5A / 02      OPERATOR SELECTED WRITE PROTECT
6 / 5A / 03      OPERATOR SELECTED WRITE PERMIT
1 / 73 / 01      POWER CALIBRATION AREA ALMOST FULL
3 / 73 / 02      POWER CALIBRATION AREA IS FULL
3 / 73 / 03      POWER CALIBRATION AREA ERROR
3 / 73 / 04      PROGRAM MEMORY AREA UPDATE FAILURE
3 / 73 / 05      PROGRAM MEMORY AREA IS FULL
5 / 2C / 03      CURRENT PROGRAM AREA IS NOT EMPTY
5 / 2C / 04      CURRENT PROGRAM AREA IS EMPTY
3 / 72 / 00      SESSION FIXATION ERROR
3 / 72 / 01      SESSION FIXATION ERROR WRITING LEAD-IN
3 / 72 / 02      SESSION FIXATION ERROR WRITING LEAD-OUT
5 / 72 / 03      SESSION FIXATION ERROR . INCOMPLETE TRACK IN SESSION
5 / 72 / 04      EMPTY OR PARTIALLY WRITTEN RESERVED TRACK

Notes:
1.  All values are in hexadecimal
2.  When no value for SK is given, the error is applicable to multiple sense keys.